Elevator smoke and draft control
Elevator smoke and draft control













elevator smoke and draft control
  1. #Elevator smoke and draft control full
  2. #Elevator smoke and draft control code
  3. #Elevator smoke and draft control series

Installed at smoke detector to monitor the circuit. Products Supplied But Not Installed Under This Section: 1. The assembly may be installed in areas where pressurization is provided to control smoke movement in accordance with Section 4.3.2 of NFPA 105 (2019) and for hoistway opening protection and lobby doorways as allowed in Chapter 30 of the 2018 IBC. Section Includes: smoke containment screen and control system designed to provide a tight-fitting, smoke- and draft-control assembly. The system will deploy only when the smoke detector in front of that particular elevator opening goes into alarm.ĪThis assembly was tested without an artificial bottom seal. System Operation: The Smoke Guard system is designed specifically to protect elevator openings and the shaft from vertical smoke migration. the requirements for a smoke and draft control door assembly tested in. Additional installation components are required for openings greater than 55-1/4 inches wide. Other types of doors, including swinging elevator doors, shall be tested in. Smoke Control have an extensive range of fire windows, fire shutters, smoke curtains, smoke containment screens and fire curtains achieving an FRL up to. The Smoke Guard M400 and M400B System application designs are for a maximum hoistway opening of 70-1/2 inches wide, and a maximum ceiling height of 144 inches. The M400B System uses standard building power and an integral battery backup system to maintain operation during building power failure. The M400 System uses standard building power. The Smoke Guard M400 and M400B Systems include a control system consisting of a printed circuit board containing the control, alarm and diagnostic logic.

#Elevator smoke and draft control code

NYC Building Code 2022 > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.7 Occupant Evacuation Elevator Lobby > 3008.7.1 Access to Interior Exit Stairway or Ramp. The smoke and draft control provision does not apply to fire door assemblies in fire barriers. The film edge is connected to flexible magnetic strips which adhere to ferrous metal rails as the system deploys creating a tight seal. The protected path shall be separated from the enclosed elevator lobby through an opening protected by a smoke and draft control assembly. The Smoke Guard System screen consists of a reinforced, transparent, polyamide or polyimide film. The Smoke Guard screen consists of a reinforced, transparent, polyimide film.

#Elevator smoke and draft control series

The test assemblies utilized integrally gasketed, series SQW and DQW frames as well as various Ceco Door types, both label and non-label.įor specific requirements on smoke control door assemblies, consult the lastest issues of NFPA 80, 101 and 105.System Description: The Smoke Guard Model 400 and Model 400B (M400 and M400B) Systems create a code-compliant smoke and draft control assembly when paired with common fire-rated elevator doors. smoke- and draft-control assembly when paired with common fire-rated elevator doors. The protected path shall be separated from the enclosed elevator lobby through an opening protected by a smoke and draft control assembly in accordance. Infiltration rates produced when assemblies are subjected to to various positive pressures, at both ambient (75 F) and elevated (400 F) temperatures. The Smoke Guard system Model 200 (M200) creates a code compliant smoke and draft control assembly when paired with common fire-rated elevator doors. Tested in accordance with Underwriter's Laboratories Test 1784 (Air Leakage Test of Door Assemblies) as indicated by NFPA 105, to ascertain the Stair Enclosures Pressurized or Non-pressurized.Weatherstrip Foam filled compression gasket minimizes air infiltration, provides better, flexible seal.

#Elevator smoke and draft control full

This system provides assurance of conformance to the most recent Positive Pressure test for fire and smoke performance.Įffective Smoke Seal - Life Safety: NFPA 105 smoke and draft control BOCA code section 1015.0 smoke enclosures: UBC sec 1005.8, openings smoke and draft control.įire Rated - 20 minute to 3 hour, UL or WH, meets National Fire codes BOCA code section 717.0 fire doors UBC section 713 fire doors, UL-10b, UL-10c, UBC-7-2 1997 "S" label.ĭoors: Flush or embossed, decorative insulated, high or low usage, 18 or 16 gauge, cold rolled or galvanized steel.Ĭoncealed Gasket maintains full clear opening with a vandal-proof gasket. In combination with the fire-rated doors used in nearly all elevators, our elevator smoke containment curtains provide comprehensive and code-compliant smoke and draft opening protection. and other pumpers drafting water from the basin to attack the fire. Smoke-Tech provides the absolute best smoke barrier protection and draft control available, and provides you with a high quality, functional, aesthetically pleasing opening. and dependence on elevators are required.















Elevator smoke and draft control